An intelligent protection scheme for series-compensated transmission lines connecting large-scale wind farms

Prabhu, M. S. and Biswas, Sauvik and Nayak, Paresh Kumar and Abdelaziz, Almoataz and El-Shahat, Adel (2023) An intelligent protection scheme for series-compensated transmission lines connecting large-scale wind farms. Frontiers in Energy Research, 11. ISSN 2296-598X

[thumbnail of pubmed-zip/versions/1/package-entries/fenrg-11-1141235/fenrg-11-1141235.pdf] Text
pubmed-zip/versions/1/package-entries/fenrg-11-1141235/fenrg-11-1141235.pdf - Published Version

Download (4MB)

Abstract

Series-compensated transmission lines (SCTLs) are increasingly preferred for transmitting bulk amounts of electricity generated from the present-day large-scale wind farm to the utility grid due to several technical and economic benefits. However, when a fault occurs in such a wind farm-integrated SCTL, the impedance across the metal oxide varistor (MOV)-protected series capacitor varies non-linearly. Also, the fault current contributed from the wind farm side is quite different compared to the grid side. Consequently, the widely used fixed impedance-based distance relaying schemes showed limitations when used for protecting such crucial TLs. In this paper, the impacts of series compensation and wind farm integration on distance relay are investigated, and this paper proposes an intelligent relaying scheme using only the current measurements. In the proposed scheme, the fault detection task is performed using the signs of the half-cycle magnitude differences of the line end positive-sequence currents, and the fault classification task is performed using only the local current measurements processed through the Fourier–Bessel series expansion (FBSE) bagging ensemble (BE) classifier. The non-stationary components present in the current signal at the initiation of a fault are captured by calculating FBSE coefficients, and the singular value decomposition is applied for dimensionality reduction of the feature set. Finally, the extracted features are used by the BE classifier for fault classification. The method is evaluated in MATLAB/Simulink® on numerous fault and non-fault data simulated in two-bus systems and also validated through the OPAL-RT (OP4510) manufactured real-time digital simulation platform. The obtained results (response time for fault detection and classification

Item Type: Article
Subjects: Open Archive Press > Energy
Depositing User: Unnamed user with email support@openarchivepress.com
Date Deposited: 25 Apr 2023 05:09
Last Modified: 20 Jul 2024 09:10
URI: http://library.2pressrelease.co.in/id/eprint/1006

Actions (login required)

View Item
View Item